ISO/TR 24422:2022 PDF

ISO/TR 24422:2022 PDF

Name:
ISO/TR 24422:2022 PDF

Published Date:
11/30/2022

Status:
Active

Description:

Development of a water equivalent phantom to measure the physical characteristics of specific radiosurgery treatment devices

Publisher:
International Organization for Standardization (Technical Report)

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$24.3
Need Help?
A water phantom is used to ensure the accurate measurement of absorbed dose delivered by a radiation therapy machine as well as standardizing the dose distribution produced by the radiation therapy device.

This document describes a detailed procedure for the construction and calibration of a polystyrene phantom and the results of its use in measuring the absorbed dose profile around the mechanical centre of a radiosurgery medical device, the full width at half maximum (FWHM) of the field and the physical penumbra at the mechanical centre, as well as the associated uncertainties.

According to IAEA TRS-483 document, the most common design recommended in Gamma Knife® system is a hemisphere atop a water filled or compact polystyrene cylinder, and when using a polystyrene phantom, the measurement depth of the absorbed dose to water is reported to be the centre of the hemisphere with the radius of 8 cm.

This document mainly describes the procedure for measuring the absorbed dose distribution around the mechanical centre of Gamma Knife® and obtaining the FWHM and penumbra from it. The developed phantom is made of polystyrene and has a hemispherical shape in accordance with the design suggested in IAEA TRS-483.

This type of phantom is specific and adapted only for the Gamma Knife® radiosurgery facilities (PerfexionTM and IconTM models) and does not apply to general dosimetry protocols in radiotherapy facilities that use a small radiation field to treat a disease such as LINAC or Cyberknife.

Considering that the type of medical device corresponds to treatment using external beam radiotherapy following small static fields, this technical report follows the recommendations published in the IAEA TRS-483.
File Size : 1 file , 1.8 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 11/30/2022

History


Related products


Best-Selling Products

ETSI Draft EN 301 908-13
Published Date: 11/01/2021
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE)
$9.81
ETSI EG 200 053
Published Date: 06/01/2004
Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio site engineering for radio equipment and systems
$9.81
ETSI EG 200 234
Published Date: 02/01/2000
Telecommunications security; A guide to specifying requirements for cryptographic algorithms
21.80 21.31 you save 0.49
ETSI EG 200 351
Published Date: 09/01/1997
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 09/01/1998
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 10/01/1999
ETSI object identifier tree; Rules and registration procedures
17.83 17.34 you save 0.49